Product Code: 6914688
Availability: In Stock
$31.27
Ex Tax: $31.27

Product Description

Features:

Display: 6000 counts

DC/AC Current Measurement
DC/AC Voltage Measurement
Resistance/Continuity/Frequency Measurement
Automatic measuring range
Full measuring range overload protection
True RMS
Auto power off
Backlight
Low Battery indication
Date hold
V-alert Test(dangerous voltage alarm)
Live wire and null wire test

Specifications:

 
Max voltage allowed at the measuring end.:600V DC or 600AC(RMS).
Work height: max 2000m
Display:LCD.
Max display value: 5999 digits.
Polarity indication:Self-indicating, ‘-’ means Negative polarity. Over-range display:‘0L’ or ‘-0L’.
Sampling time:The meter figures show about 0.4 seconds
Unit display
:
Function and battery unit display.
Automatic Power off time: 15 minutes
Operational power
:1.5Vx2 AAA battery.(not included)
Battery low voltage indication: LCD display symbol.
Temperature coefficient:Less than 0.1 x Accuracy / ℃
Operational temperature and humidity : 0~40 ℃/32~104℉ 45%-80%RH
Storage temperature and humidity
:-10~60 ℃/-4~140℉ 45%-80%RH
Boundary dimension
:
139×83×36mm
Weight: ~160g

1. Voltage DC
 

RangeResolutionAccuracy
600V0.1V±(0.8%+3counts)

Sensitivity: min 0.5V DC voltage Input impedance: 1MΩ
Max input voltage
:600V DC&AC (RMS)

2. Voltage AC
 

RangeResolutionAccuracy
600V0.1V±(1.2%+5counts)

Sensitivity: min 0.5V DC voltage Input impedance: 1MΩ
Max input voltage
:600V DC&AC (RMS)
Frequency range: 50Hz~60Hz, true RMS response.
 
3. Resistance
 

RangeResolutionAccuracy
6000Ω±(1.2% +3counts)

Overload protection:600V DC or AC(RMS)
 
4. Current DC
 

RangeResolutionAccuracy
200mA0.1mA±(1.2%+3 counts)

Sensitivity: min 0.5mA DC current.
Overload protection
:600V/200mA self-recovery fuse. Frequency range: 50Hz~60Hz.
 
5. Current AC
 

RangeResolutionAccuracy
200mA0.1mA±(1.5%+5counts)

Sensitivity: min 1mA AC current.
Overload protection: 600V/200mA self-recovery fuse. Frequency range: 50Hz~60Hz.

6. Frequency

RangeResolutionAccuracy
1000Hz1Hz±(1.0%+5counts)

Frequency range: 40Hz~1000Hz.
 
7. Measure Continuity
 

FunctionAccuracy
 
buzzer
If the resistance is <30Ω,
the continuity beeper
sounds.

Overload protection:6000V DC or AC(RMS)
 
8. V~Alert
 

RangeExplanation
Low fileShow -EF-, green V~Alert light continue light on, the beep sounds
Hgh fileShow -EF-, red NCV light continue light on, the buzzer sounds an alarm
at a higher frequency

Package Includes:

1 x 1 x Pair of Probes 
1 x English User Manual
1 x Package Box

Detail Pictures:










Write a review

Note: HTML is not translated!